Customer Service: 1-844-695-1494
Free Shipping Over $150
Sourcing & Procurement
Volume Discounts
Why Shop Owl Medical?
SIGN IN / CREATE ACCOUNT
Cart 0
Menu
Cart 0
...

Welch Allyn 44WT-B Spot 4400 with NIBP, SureTemp Thermometer and Nonin® SpO2

Box of 1

  • $5,017.99 CAD


  • The Spot Vital Signs 4400 Device delivers a digital, consolidated way to capture your patient’s vitals with a simple touchscreen display.

    Features and Benefits

    • SureBP technology, capable of a 15-second BP determination
    • Blood Pressure averaging capability to help ensure accurate hypertension diagnosis
    • Built-in SureTemp plus oral / axillary thermometry
    • Easy to use color touchscreen display
    • EMR connectivity helps minimize documentation errors
    • 8-hour Lithium ion battery to maximize time before recharging
    • 7" color touchscreen for a simplified workflow
    • Optional Nonin SpO2 available
    Materials Included
    • Spot 4400 Vital Signs Model
    • (1) Adult Blood Pressure Cuff
    • (1) Blood Pressure Hose
    • (1) SureTemp Thermometer
    • (1) Nonin Adult SpO2 Finger Sensor (Optional)
    • User Manual
    Technical Specifications
    • Dimensions
      • Height: 10.1"
      • Width: 9.3"
      • Depth: 4.9"
    • Non-Invasive Blood Pressure (NIBP)
      • Cuff Pressure Range: Meets or Exceeds IEC/ISO 80601-2-30 Standard for Cuff Pressure Range
      • Systolic Range
        • Adult: 30 – 260 mmHg (StepBP, SureBP)
        • Pediatric: 30 – 260 mmHg (StepBP, SureBP)
      • Diastolic Range
        • Adult: 20 – 220 mmHg (StepBP, SureBP)
        • Pediatric: 20 – 220 mmHg (StepBP, SureBP)
      • Cuff Inflation Target
        • Adult: 160 mmHg (StepBP)
        • Pediatric: 140 mmHg (StepBP)
      • Maximum Target Pressure
        • Adult: 280 mmHg (StepBP, SureBP)
        • Pediatric: 280 mmHg (StepBP, SureBP)
      • Blood Pressure Determination Time
        • Typical: 15 seconds
        • Maximum: 150 seconds
      • Blood Pressure Accuracy
        • Meets or Exceeds ISO 81060-2:2013 Standards for NIBP (± 5 mmHg mean error, 8 mmHg standard deviation)
      • Mean Arterial Pressure (MAP) Range:
        • Adult: 23 – 230 mmHg (StepBP, SureBP)
        • Pediatric: 23 – 230 mmHg (StepBP, SureBP)
      • Pulse Rate Range (Using Blood Pressure Determination)
        • Adult: 30 – 200 bpm (StepBP, SureBP)
        • Pediatric: 30 – 200 bpm (StepBP, SureBP)
      • Pulse Rate Accuracy (Using Blood Pressure Determination)
        • ± 5.0% (± 3 bpm)
      • Overpressure Cutoff
        • Adult: 300 mmHg ± 15 mmHg
        • Pediatric: 300 mmHg ± 15 mmHg
    • SureTemp Plus® Temperature Module
      • Temperature Range (All Measurement Sites): 80°F – 110°F (26.7°C – 43.3°C)
    • Nonin SpO2 Specifications
      • SpO2 Performance Measurement Range: 1% - 100%
      • Pulse Rate: 18 – 300 bpm: ± 3 digits; Low perfusion (40 – 240 bpm): ± 3 digits
      • Saturation: 70 - 100%
    • Saturation Variance
      • Adult/Pediatrics, No Motion
        • Finger Clip: ± 2 digits
        • Flex: ± 3 digits
      • Adult/Pediatrics, Motion
        • Finger Clip: ± 2 digits
        • Flex: ± 3 digits
      • Adult/Pediatrics, Low Perfusion
        • All Sensors: ± 2 digits